This product presents with a risk of electric shock because it is designed as a double‑insulated electrical appliance, meaning that a second protective insulation must prevent user exposure in case the basic insulation fails. The manufacturer has identified that, in certain identification numbers, an external aluminium part accessible to the user may come into contact with the aluminium motor support if the first insulation layer fails. If an internal insulation fault occurred between the motor winding and the motor support, the fault could be transmitted to the accessible aluminium part, potentially exposing the user to electric shock. This product does not meet safety standards.
Models and product ranges affected:
- XM-21: 3030625 / 3030748 / 3030750.
- XM-22: 3030626 / 3030629 / 3030754 / 3030756.
- MB-21: 3030634 / 3030639 / 3030760 / 3030762.
- MB-22: 3030763
- B-20: 3030636 / 3030766 / 3030768.
- MM-20V: 3030637.
- MM-20: 3030742 / 3030744.
- XM-31: 3030671 / 3030672 / 3030784 / 3030786.
- XM-32: 3030673 / 3030674 / 3030790 / 3030792.
- XM-33: 3030675 / 3030787 / 3030791 / 3030793.
- MB-31: 3030676 / 3030796 / 3030798 / 3030805.
- B-30: 3030669 / 3030802 / 3030804.
- MM-30V: 3030667 / 3030778 / 3030780.
- MM-30: 3030666 / 3030772 / 3030774.
Description:
Portable electric liquidiser for commercial use. The product has been recalled by the manufacturer. For more information, please access: https://sammic-com.web.app/en/recall-xm or contact recallexport@sammic.com.
|